  1.       
  2.  
  3.                                   SF-WIN.DOC
  4.                     Running SPITFIRE v3.3 with Windows 3.x 
  5.          
  6.                               SPITFIRE - Version 3.3
  7.                     Copyright (C) by Mike Woltz, 1987-1993
  8.                               Buffalo Creek Software
  9.  
  10.  
  11.  
  12.         RUNNING SPITFIRE WITH WINDOWS 3.X
  13.         ---------------------------------
  14.  
  15.             In order to run SPITFIRE v3.3 under MS Windows 3.X, Sysops need to
  16.         create a PIF (Program Information File). Windows uses PIFs to run DOS
  17.         applications.  A PIF file tells Windows the name and the location of
  18.         the DOS (non-Windows application) program being run and describes the
  19.         necessary memory and hardware requirements.  A PIF file is required
  20.         whether running a single node or a multi-node BBS.
  21.  
  22.             To create a PIF file, Sysops must run the PIF editor which is
  23.         located in the Accessories Group.
  24.  
  25.         Memory Requirements:
  26.         -------------------
  27.  
  28.             Windows sets a MINIMUM value of 128K for all programs that it runs
  29.         via a PIF file. However, Windows assigns ALL available memory to all
  30.         PIF applications unless told to do otherwise.  Even though SPITFIRE
  31.         normally requires more than 128K to run, you will probably not need
  32.         to increase this value.
  33.  
  34.             Sysops who intend to drop to DOS from the SPITFIRE window and
  35.         are running in Real or Standard Mode could increase the memory
  36.         requirements. In 386 Enhanced Mode, a better way would be to open
  37.         another DOS window.
  38.  
  39.             All other values are the Windows default PIF values.  If running
  40.         Windows 3.X in 386 Enhanced Mode, click on ADVANCED options to examine
  41.         additional parameters and settings.  It is not possible to see these
  42.         settings while running in Real or Standard Mode without pulling down
  43.         the Mode Option and select 386 Enhanced Mode.  Enhanced options are
  44.         meaningless when running Windows in Real or Standard Modes. Under
  45.         Multitasking Options (ADVANCED), set both Background Priority and
  46.         Foreground Priority to 50 for more equitable sharing of time slices
  47.         between windows.
  48.  
  49.         Hardware Requirements:
  50.         ---------------------
  51.  
  52.             To run multiple active SPITFIRE windows on the screen, Sysops MUST
  53.         run in 386 Enhanced Mode.  This REQUIRES a 386SX or 386DX CPU. 2MB of
  54.         RAM is recommended, but the more the better!  Sysops MUST install the
  55.         HIMEM.SYS driver that is included on the Windows 3.X diskettes
  56.         according to parameters applicable to their systems. The popular
  57.         QEMM386 program (Version 5.1 and greater) may be substituted for
  58.         HIMEM.SYS with appropriate parameters. Sysops should ideally be running
  59.         the SMARTDRV cache program as it is designed to work with Windows.
  60.         Remember to load ANSI.SYS in your CONFIG.SYS if ANSI graphics is
  61.         available on the BBS!
  62.  
  63.             Sysops running the BBS on an 8086, 8088 or 80286 can run SPITFIRE
  64.         while running Windows, but it will NOT run in a window.  It will
  65.         instead run in "exclusive mode", that is to say, full screen. When
  66.         switching back to the main Windows screen, SPITFIRE will "freeze"
  67.         (as will any other DOS application.) Running an application in this
  68.         manner is generally referred to as running "under" windows as opposed
  69.         to running "in" windows which refers to the 386 Enhanced "in a
  70.         window" style.
  71.  
  72.         Additional Information:
  73.         ----------------------
  74.  
  75.             To run SPITFIRE v3.3 in a DOS window, select Background and Windowed
  76.         as options when creating your SPITFIRE PIF file. This will allow
  77.         viewing of one or several nodes on the screen at the same
  78.         time as well as other Windows applications. Background windows do not
  79.         "freeze" when you are running Windows in 386 Enhanced Mode.
  80.  
  81.             If running a multi-node setup, it is suggested to name the batch
  82.         files and PIF files based upon their node number (SF1.BAT, SF1.PIF,
  83.         etc.) In addition, there are Windows applications which allow creation
  84.         of custom Icons which are unique for each node.
  85.  
  86.             To load Windows automatically and have it bring up the SPITFIRE
  87.         window(s), first edit AUTOEXEC.BAT and have it run WIN.COM. Next,
  88.         edit WIN.INI, and set "RUN=SF1.BAT SF2.BAT", etc. to automatically
  89.         boot up all SPITFIRE nodes. Make sure to leave a space between all
  90.         items listed on the WIN.INI "RUN=" line. If running Windows 3.1 or
  91.         greater, all SF.BAT files can be placed in the StartUp Group which
  92.         will automatically run them when Windows 3.1 loads.
  93.  
  94.             When configuring SPITFIRE to operate multi-node in the Windows
  95.         environment and when attempting to boot node 2 you incur a
  96.         runtime error 162, this is caused by having the DOS SHARE loaded
  97.         in memory.  A runtime error 162 is hardware failure.